- d2of5 - Variable in class com.symbol.emdk.barcode.ScannerConfig.DecoderParams
-
The D2OF5 class provides access to parameters that are available for
the D2OF5 decoder.
- d2of5 - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.Decoders
-
Deprecated.
Sets the Enabled State of Decoder Discrete 2 of 5.
- data - Variable in class com.symbol.emdk.simulscan.SimulScanElement
-
- databar_to_upc_ean - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.UpcEanParams
-
Deprecated.
If this is set it converts DataBar bar codes to UPC/EAN format.
- dataBit - Variable in class com.symbol.emdk.serialcomm.SerialCommConfig
-
The number of data bits for each character.
- dataCapture - Variable in class com.symbol.emdk.ProfileConfig
-
Deprecated.
- datacapture_led_id - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ScanParams
-
Deprecated.
- dataDelivery - Variable in class com.symbol.emdk.ProfileConfig.DataCapture
-
Deprecated.
Gets and Sets DataDelivery configuration object.
- dataFileSettings - Variable in class com.symbol.emdk.securenfc.MifareDesfire.FileTypeSpecificSettings
-
Standard data or Backup data file specific settings
- dataMatrix - Variable in class com.symbol.emdk.barcode.ScannerConfig.DecoderParams
-
The DataMatrix class provides access to parameters that are available
for the DataMatrix decoder.
- datamatrix - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.Decoders
-
Deprecated.
Sets the Enabled State of Decoder Data Matrix.
- debit(byte, MifareDesfire.FileCommMode, int) - Method in class com.symbol.emdk.securenfc.MifareDesfire
-
Decreases value stored in a value file with specified value.Depending on
communication settings of file, data read from card will be either plain
or enciphered.
- debugMode - Variable in class com.symbol.emdk.simulscan.SimulScanConfig
-
If enabled, allows a session to write form capture, region images, region values, and other data to storage.
- decode_audio_feedback_uri - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ScanParams
-
Deprecated.
Select an audio tone to sound upon a good decode.
- decode_haptic_feedback - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ScanParams
-
Deprecated.
Enable the device to vibrate upon a good decode (default - enabled).
- decodeAudioFeedbackMode - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Controls the audio feedback mode.
- decodeAudioFeedbackUri - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Select an audio tone to sound upon a good decode.
- decodeHapticFeedback - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Enable the device to vibrate upon a good decode.
- decodeLEDFeedback - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Decoding LED Notification.
- decodeLEDFeedbackMode - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Controls the LED feedback mode.
- decodeLEDTime - Variable in class com.symbol.emdk.barcode.ScannerConfig.ScanParams
-
Decode LED ON duration upon successful decode in milliseconds.
- decoderParams - Variable in class com.symbol.emdk.barcode.ScannerConfig
-
The DecoderParams class contains decoder parameters that are used by
multiple decoder symbologies.
- decoderParams - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode
-
Deprecated.
- decoders - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode
-
Deprecated.
- decoding_led_feedback - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ScanParams
-
Deprecated.
Enable the device to blink LED upon a good decode (default - disabled).
- decrement(boolean, short, int) - Method in class com.symbol.emdk.securenfc.MifarePlusSL3
-
Decrements contents of given value block by specified value and stores
result in transfer buffer.
- decrementTransfer(boolean, short, short, int) - Method in class com.symbol.emdk.securenfc.MifarePlusSL3
-
Performs combined operation of decrement() and transfer() on specified
value block.
- delivery - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.DataDelivery.Intent
-
Deprecated.
- DEVICE_IDENTIFIER - Static variable in class com.symbol.emdk.barcode.TokenizedData.Keys
-
- deviceIdentifier - Variable in class com.symbol.emdk.scanandpair.ScanAndPairConfig.ScanInfo
-
Specifies the type of scanner to be used for scanning the barcode.
- deviceIdentifier - Variable in class com.symbol.emdk.simulscan.SimulScanReaderInfo
-
- DeviceInfo - Class in com.symbol.emdk.notification
-
DeviceInfo provides information of the notification device.
- deviceName - Variable in class com.symbol.emdk.scanandpair.ScanAndPairConfig.BluetoothInfo
-
Specifies the Bluetooth name of the remote device.
- DeviceType - Enum in com.symbol.emdk.notification
-
- deviceType - Variable in class com.symbol.emdk.simulscan.SimulScanReaderInfo
-
- Diagnostic - Class in com.symbol.emdk.personalshopper
-
This class provides access to fetch the diagnostics information.
- diagnostic - Variable in class com.symbol.emdk.personalshopper.PersonalShopper
-
The field to access the diagnostics feature.
- DiagnosticConfig - Class in com.symbol.emdk.personalshopper
-
The diagnostic configuration class has to be configured before calling the get diagnostics parameter data.
- DiagnosticConfig(int, int) - Constructor for class com.symbol.emdk.personalshopper.DiagnosticConfig
-
DiagnosticsConfig Constructor
- DiagnosticData - Class in com.symbol.emdk.personalshopper
-
The diagnostic data.
- DiagnosticException - Exception in com.symbol.emdk.personalshopper
-
The methods of diagnostic API throw a DiagnosticException when an error
occurs.
- DiagnosticParamId - Class in com.symbol.emdk.personalshopper
-
The diagnostic parameter IDs.
- DiagnosticParamId() - Constructor for class com.symbol.emdk.personalshopper.DiagnosticParamId
-
- DiagnosticResults - Enum in com.symbol.emdk.personalshopper
-
Defines all the error codes the diagnostic API returns.
- different_barcode_timeout - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ReaderParams
-
Deprecated.
This setting is used to prevent the scanner from decoding another symbol within this time interval (applicable only when
aim_type = AIM_TYPE.CONTINUOUS_READ).
- differentSymbolTimeout - Variable in class com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.CameraSpecific
-
This setting is used to prevent the scanner from decoding another symbol within this time interval.
- differentSymbolTimeout - Variable in class com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.ContinuousRead
-
- differentSymbolTimeout - Variable in class com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific
-
This setting is used to prevent the scanner from decoding another symbol within this time interval.
- differentSymbolTimeout - Variable in class com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific
-
This setting is used to prevent the scanner from decoding another symbol within this time interval.
- disable() - Method in class com.symbol.emdk.barcode.Scanner
-
Disables the scanner hardware.
- disable() - Method in class com.symbol.emdk.notification.NotificationDevice
-
Disables the notification device.
- disable() - Method in class com.symbol.emdk.personalshopper.Cradle
-
This disables communication to interact with the cradle.
- disable() - Method in class com.symbol.emdk.securenfc.MifareDesfire
-
Disables I/O operations to the tag from IsoDep object and SAM
communication.
- disable() - Method in class com.symbol.emdk.securenfc.MifarePlusSL3
-
Disables I/O operations to the tag from IsoDep object, closes connection
to SAM, and releases resources.
- disable() - Method in class com.symbol.emdk.securenfc.PassThruApduProcessor
-
Closes already established connection between host device and SAM.
- disable() - Method in class com.symbol.emdk.serialcomm.SerialComm
-
This method disables USB/serial channel to communicate with the remote device.
- disable() - Method in class com.symbol.emdk.simulscan.SimulScanReader
-
Disables the reader hardware.
- disconnectOnExit - Variable in class com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.ImagerSpecific
-
This parameter indicates to the scan driver to disconnect any existing connection between an
external Bluetooth scanner and the terminal.
- discrete_2of5 - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.DecoderParams
-
Deprecated.
- display_bt_address_barcode - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.ScanParams
-
Deprecated.
If this value is set to true, the Bluetooth Pairing Utility
Application will be opened when the enable method is called.
- displayBluetoothAddressBarcode - Variable in class com.symbol.emdk.barcode.InterfaceConfig
-
When using Bluetooth (Imager) scanners, the pairing process between the mobile computer and Bluetooth scanner
may require scanning the Bluetooth address of the mobile computer.
- diverseInput - Variable in class com.symbol.emdk.securenfc.SamDiverseParams
-
Diversification input data Data length: 8 bytes (3DES) or 16 bytes (AES)
for SAM AV1 or SAM AV2 in AV1 compatibility mode 1-15 bytes (3DES) or
1-31 bytes (AES) for SAM AV2 in AV2 mode
- diverseMode - Variable in class com.symbol.emdk.securenfc.SamDiverseParams
-
Key diversification mode to be used false: AV1 true: AV2
- DONATION_ID - Static variable in class com.symbol.emdk.barcode.TokenizedData.Keys
-
- dutch_postal - Variable in class com.symbol.emdk.ProfileConfig.DataCapture.Barcode.Decoders
-
Deprecated.
Sets the Enabled State of Decoder Dutch Postal.
- dutchPostal - Variable in class com.symbol.emdk.barcode.ScannerConfig.DecoderParams
-
The DutchPostal class provides access to parameters that are
available for the DutchPostal decoder.