This section covers common errors that can occur when using StageNow and offers advice on how to address them.
Exporting Profiles
Frequently Asked Questions
Q: Why can exported locked Profiles be opened only with StageNow 5.23?
Profiles exported with the "Lock the Profile on Export" feature selected are protected with stronger encryption than that used in prior StageNow versions. This change provides far greater security for exported files than in previous versions.
This change does not effect Profiles that are not locked.
Q: Can Profiles exported from older StageNow versions be imported with 5.23?
Yes. StageNow 5.23 and later can import all Profiles exported from prior versions, regardless of whether they are locked or unlocked.
Q: Can a Profile be exported from StageNow 5.23 into an older StageNow version?
It depends. A Profile can be exported for use with older StageNow versions only if it was exported without "Lock the profile on Export" selected. Older versions can't open locked Profiles exported from 5.23 or later, and a locked Profile cannot be unlocked. If there's a chance that a Profile might be needed by someone using a version prior to StageNow 5.23, consider keeping an unlocked copy of the Profile for sharing.
Zebra recommends using the latest version of StageNow at all times.
Q: Do existing Profiles created with older StageNow versions need to be exported again after upgrading?
No. Existing Profiles can be imported without modification. Also, exporting a Profile with StageNow 5.23 that had been locked using a previous StageNow version upgrades its encryption to the current strength.
Q: Does this change effect barcodes or Profiles already deployed?
No. This change applies only to files containing Profiles exported from (and imported into) the StageNow desktop tool.
Q: Why does this dialog box appear when trying to export a Profile?
Click image to enlarge; ESC to cancel.
When exporting a Profile from the StageNow 5.23 desktop tool, the admin is prompted to lock the exported Profile to prevent unauthorized changes. Checking the box encrypts the Profile, rendering it unreadable by any means except StageNow.
Learn more from this Zebra Knowledge Center article.
Troubleshooting
XML Configuration Failure

Problem
The message "FMC download FTP File Read timed out" (or similar) appears in the device when staging completes.
Cause
This error generally occurs when FTP is used during staging to download a large file (greater than 1.5 GB) from a public server.
Solution
Try using FTPS instead of FTP for the file transfer.
Wi-Fi Hotspot
NOTE: Wi-Fi Hotspot staging is NOT supported on systems running Windows 10.

Problem
The message "Unable to turn on the Wi-Fi Hotspot" (or similar) appears when attempting to turn on the StageNow Wi-Fi Hotspot feature.
Cause
This can occur if the Wi-Fi adapter in the host PC is not initialized or is inactive when StageNow launches.
Solution
Try the following steps to resolve the issue:
Restart Wi-Fi Adapter
Right-click on the Network icon on the bottom right corner of the Windows host and select Open Network and Sharing Center to open the following screen.

On the left pane, select Change adapter settings.

Open a command prompt and enter "netsh wlan show drivers" to find the Wi-Fi driver adapter name.

Right-click on the network adapter in the Network Connections window and select Disable.
Right-click again and select Enable. After a few minutes, try using the StageNow Tool.
Add Unsupported Hotspot
Note: Results that deviate from the following can be considered a Windows driver/software issue regarding the Wi-Fi hotspot.
Open a command prompt as an Administrator.
Enter "netsh wlan show drivers" and locate the result message outlined in green below.

The following message appears if the system does not support the Wi-Fi hotspot.

Enter the following command in the command prompt: "netsh wlan set hostednetwork mode=allow ssid=
key= "" Note: HotspotName is the name of Wi-Fi hotspot.
HotspotPassword is the Wi-Fi hotspot password and must be at least 5 characters.
The following result appears after successful creation of the Wi-Fi hotspot.

Enter "netsh wlan start hostednetwork" to start the hotspot.

Enter "netsh wlan stop hostednetwork" to stop the hotspot.

Downloaded file Corrupted
Problem
The message "Downloaded file is corrupted, this may be due to instable network connection" (or similar) appears when attempting to perform the "Transfer/Copy File" Action to transfer a file from the admin host PC to a device.
Cause
This is due to checksum mismatch between source and destination files.
Solution
Try the following steps to resolve the issue:
- If the Profile was created on PC other than the one on which the error occurred and imported into StageNow:
- a. Navigate to the FileMgr section of the imported Profile
- b. Edit the Source Path and File parameter so the path to the file to be copied matches that of the PC currently in use
- c. Save changes and generate a new barcode
- If the Profile was created on the admin host PC currently in use:
- a. Navigate to the
%appdata%\StageNow\AST\FTP\PROFILESfolder on the admin host PC - b. Delete the checksum file found there
- c. Save changes and generate a new barcode
- a. Navigate to the
Plug-in CSP Issues
Profiles created with plug-in CSPs behave differently than those made with built-in CSPs. The most important difference involves Profile importation and deletion.
Click image to enlarge; ESC to cancel.
Problem
An error occurs when attempting to delete an .apk imported into the CSP library as a plug-in CSP.
Solution
- Export all profiles to a location on the administrator host PC.
- Delete the StageNow DB from the %appdata% directory on the PC.
- Re-import the exported profiles.