UsPlanet Decoder

RhoElements 2.x API

Overview

The UsPlanet Decoder is used to enable or disable the usplanet decoder.

Syntax

usPlanet (Decoder) <META> Syntax

<META HTTP-Equiv="scanner" content="usplanet:[parameter]">

usPlanet JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the usPlanet.
To Set usPlanet parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.usPlanet = Value;

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

NamePossible ValuesDescriptionDefault Value
usPlanet:[Value] enabled/disabledEnables/Disables the usplanet decoder.Device specific

Requirements

RhoElements Version1.0.0 or above
Supported DevicesAll supported devices.
Minimum RequirementsScanner or Imager module and device that supports usplanet.
PersistenceTransient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only usplanet labels:

<META HTTP-Equiv="scanner" Content="allDecoders:disabled">
<META HTTP-Equiv="scanner" Content="usplanet:enabled">
<META HTTP-Equiv="scanner" Content="enabled">

The following example enables the scanner to read only usplanet labels:

<META HTTP-Equiv="scanner" Content="allDecoders:disabled;usplanet:enabled;enabled">

The following example enables the scanner to read only usplanet labels:

<META HTTP-Equiv="scanner-all_decoders" Content="disabled">
<META HTTP-Equiv="scanner-usplanet" Content="enabled">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">

The following example enables the scanner to read all labels except usplanet:

<META HTTP-Equiv="scanner" Content="allDecoders:enabled">
<META HTTP-Equiv="scanner" Content="usplanet:disabled">
<META HTTP-Equiv="scanner" Content="enabled">