Upce0reportCheckDigit Decoder Setting

RhoElements 2.x API

Overview

The Upce0reportCheckDigit Decoder Setting is used to set the upce0 ReportCheckDigit property which enables reporting of the bar code check digit(s).

Syntax

upce0reportCheckDigit (Decoder Setting) <META> Syntax

<META HTTP-Equiv="scanner" content="upce0ReportCheckDigit:[parameter]">

upce0reportCheckDigit JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the upce0reportCheckDigit.
To Set upce0reportCheckDigit parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.upce0reportCheckDigit = Value;

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

NamePossible ValuesDescriptionDefault Value
upce0reportCheckDigit:[Value] true/falseEnables/Disables reporting of the check digit.Device specific

Requirements

RhoElements Version1.0.0 or above
Supported DevicesAll supported devices.
Minimum RequirementsScanner or Imager module and device that supports upce0.
PersistenceTransient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only upce0 labels with the ReportCheckDigit property set:

<META HTTP-Equiv="scanner" Content="upce0:enabled">
<META HTTP-Equiv="scanner" Content="upce0ReportCheckDigit:true">
<META HTTP-Equiv="scanner" Content="enabled">

Above example can also be written as shown below:

<META HTTP-Equiv="scanner" Content="upce0:enabled;upce0ReportCheckDigit:true;enabled">

or

<META HTTP-Equiv="scanner-upce0" Content="enabled">
<META HTTP-Equiv="scanner-upce0ReportCheckDigit" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">