Overview
The UpcEanLinearDecode Decoder Setting is used to enable the linear decode property.
Syntax
upcEanLinearDecode (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="upcEanLinearDecode:[parameter]"> |
upcEanLinearDecode JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the upcEanLinearDecode. |
To Set upcEanLinearDecode parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.upcEanLinearDecode = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
upcEanLinearDecode:[Value] | true/false | Sets the linear decode property to 'true' or 'false'. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices except: Enterprise Tablet. |
Minimum Requirements | Scanner or Imager module and device that supports the upcEanLinearDecode property. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example switches on the upcEanLinearDecode property:
<META HTTP-Equiv="scanner" Content="allDecoders:enabled">
<META HTTP-Equiv="scanner" Content="upcEanLinearDecode:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="allDecoders:enabled;upcEanLinearDecode:true;enabled">
or
<META HTTP-Equiv="scanner-all_decoders" Content="enabled">
<META HTTP-Equiv="scanner-upcEanLinearDecode" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">