Overview
The UkPostalreportCheckDigit Decoder Setting is used to set the ukPostal ReportCheckDigit property which enables reporting of the bar code check digit(s).
Syntax
ukPostalreportCheckDigit (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="ukPostalreportCheckDigit:[parameter]"> |
ukPostalreportCheckDigit JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the ukPostalreportCheckDigit. |
To Set ukPostalreportCheckDigit parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.ukPostalreportCheckDigit = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
ukPostalreportCheckDigit:[Value] | true/false | Enables reporting of the check digit. | false |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | Enterprise Tablet only. |
Minimum Requirements | Scanner or Imager module and device that supports ukPostal. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only ukPostal labels with the ReportCheckDigit property set:
<META HTTP-Equiv="scanner" Content="ukPostal:enabled">
<META HTTP-Equiv="scanner" Content="ukPostalreportCheckDigit:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="ukPostal:enabled;ukPostalreportCheckDigit:true;enabled">
or
<META HTTP-Equiv="scanner-ukPostal" Content="enabled">
<META HTTP-Equiv="scanner-ukPostalreportCheckDigit" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">