Overview
The UkPostal Decoder is used to enable or disable the UKPostal decoder.
Syntax
ukPostal (Decoder) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="UKPostal:[parameter]"> |
ukPostal JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the ukPostal. |
To Set ukPostal parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.ukPostal = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
ukPostal:[Value] | enabled/Disabled | Enables/Disables the UKPostal decoder. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports UKPostal. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only UKPostal labels:
<META HTTP-Equiv="scanner" Content="allDecoders:disabled">
<META HTTP-Equiv="scanner" Content="UKPostal:enabled">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="allDecoders:disabled;UKPostal:enabled;enabled">
or
<META HTTP-Equiv="scanner-all_decoders" Content="disabled">
<META HTTP-Equiv="scanner-UKPostal" Content="enabled">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">
The following example enables the scanner to read all labels except UKPostal:
<META HTTP-Equiv="scanner" Content="allDecoders:enabled">
<META HTTP-Equiv="scanner" Content="UKPostal:disabled">
<META HTTP-Equiv="scanner" Content="enabled">