MsiCheckDigits Decoder Setting

RhoElements 2.x API

Overview

The MsiCheckDigits Decoder Setting is used to set the msi checkdigits property.

Syntax

msiCheckDigits (Decoder Setting) <META> Syntax

<META HTTP-Equiv="scanner" content="msicheckdigits:[parameter]">

msiCheckDigits JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the msiCheckDigits.
To Set msiCheckDigits parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.msiCheckDigits = Value;

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

NamePossible ValuesDescriptionDefault Value
msiCheckDigits:[Value] one/twoSets the msi checkdigits property to one or two.Device specific

Requirements

RhoElements Version1.0.0 or above
Supported DevicesAll supported devices.
Minimum RequirementsScanner or Imager module and device that supports MSI.
PersistenceTransient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only msi labels with the checkdigits property set:

<META HTTP-Equiv="scanner" Content="msi:enabled">
<META HTTP-Equiv="scanner" Content="msicheckdigits:one">
<META HTTP-Equiv="scanner" Content="enabled">

Above example can also be written as shown below:

<META HTTP-Equiv="scanner" Content="msi:enabled;msicheckdigits:one;enabled">

or

<META HTTP-Equiv="scanner-msi" Content="enabled">
<META HTTP-Equiv="scanner-msicheckdigits" Content="one">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">