MacroMicroPdf Decoder

RhoElements 2.x API

Overview

The MacroMicroPdf Decoder is used to enable or disable the MacroMicroPDF decoder.

Syntax

macroMicroPdf (Decoder) <META> Syntax

<META HTTP-Equiv="scanner" content="MacroMicroPDF:[parameter]">

macroMicroPdf JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the macroMicroPdf.
To Set macroMicroPdf parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.macroMicroPdf = Value;

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

NamePossible ValuesDescriptionDefault Value
macroMicroPdf:[Value] enabled/disabledEnables/disables the MacroMicroPDF decoder.Device specific

Requirements

RhoElements Version1.0.0 or above
Supported DevicesAll supported devices except: Enterprise Tablet.
Minimum RequirementsScanner or Imager module and device that supports MacroMicroPDF.
PersistenceTransient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only MacroMicroPDF labels:

<META HTTP-Equiv="scanner" Content="allDecoders:disabled">
<META HTTP-Equiv="scanner" Content="MacroMicroPDF:enabled">
<META HTTP-Equiv="scanner" Content="enabled">

Above example can also be written as shown below:

<META HTTP-Equiv="scanner" Content="allDecoders:disabled;MacroMicroPDF:enabled;enabled">

or

<META HTTP-Equiv="scanner-all_decoders" Content="disabled">
<META HTTP-Equiv="scanner-MacroMicroPDF" Content="enabled">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">

The following example enables the scanner to read all labels except MacroMicroPDF:

<META HTTP-Equiv="scanner" Content="allDecoders:enabled">
<META HTTP-Equiv="scanner" Content="MacroMicroPDF:disabled">
<META HTTP-Equiv="scanner" Content="enabled">