Overview
The I2of5verifyCheckDigit Decoder Setting is used to set the i2of5 VerifyCheckDigit property which enables verification of the bar code check digit.
Syntax
i2of5verifyCheckDigit (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="i2of5VerifyCheckDigit:[parameter]"> |
i2of5verifyCheckDigit JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the i2of5verifyCheckDigit. |
To Set i2of5verifyCheckDigit parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.i2Of5verifyCheckDigit = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
i2Of5verifyCheckDigit:[Value] | none/USS/OPCC | if value is "none" Disables verification of the check digit.if value is "USS" Enables the USS format for the check digit. .if value is OPCC Enables the OPCC format for the check digit. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports i2of5. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only i2of5 labels with the VerifyCheckDigit property set to uSS:
<META HTTP-Equiv="scanner" Content="i2of5:enabled">
<META HTTP-Equiv="scanner" Content="i2of5VerifyCheckDigit:USS">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="i2of5:enabled;i2of5VerifyCheckDigit:USS;enabled">
or
<META HTTP-Equiv="scanner-i2of5" Content="enabled">
<META HTTP-Equiv="scanner-i2of5VerifyCheckDigit" Content="USS">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">