Overview
The I2of5reportCheckDigit Decoder Setting is used to set the i2of5 ReportCheckDigit property which enables reporting of the bar code check digit(s).
Syntax
i2of5reportCheckDigit (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="i2of5ReportCheckDigit:[parameter]"> |
i2of5reportCheckDigit JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the i2of5reportCheckDigit. |
To Set i2of5reportCheckDigit parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.i2of5reportCheckDigit = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
i2of5reportCheckDigit:[Value] | true/false | Enables/Disables reporting of the check digit. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports i2of5. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only i2of5 labels with the ReportCheckDigit property set:
<META HTTP-Equiv="scanner" Content="i2of5:enabled">
<META HTTP-Equiv="scanner" Content="i2of5ReportCheckDigit:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="i2of5:enabled;i2of5ReportCheckDigit:true;enabled">
or
<META HTTP-Equiv="scanner-i2of5" Content="enabled">
<META HTTP-Equiv="scanner-i2of5ReportCheckDigit" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">