Overview
The I2of5convertToEan13 Decoder Setting is used to enable conversion from i2of5 to EAN13 bar code. If this flag is set, the bar code is converted to EAN13, and EAN13 parameters are used.
Syntax
i2of5convertToEan13 (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="i2of5ConvertToEAN13:[parameter]"> |
i2of5convertToEan13 JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the i2of5convertToEan13. |
To Set i2of5convertToEan13 parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.i2of5convertToEan13 = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
i2of5convertToEan13:[Value] | true/false | Enables/Disables the property. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports i2of5 and ean13. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only i2of5 labels with the ConvertToEAN13 property set:
<META HTTP-Equiv="scanner" Content="i2of5:enabled">
<META HTTP-Equiv="scanner" Content="ean13:enabled">
<META HTTP-Equiv="scanner" Content="i2of5ConvertToEAN13:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="i2of5:enabled;ean13:enabled;i2of5ConvertToEAN13:true;enabled">
or
<META HTTP-Equiv="scanner-i2of5" Content="enabled">
<META HTTP-Equiv="scanner-ean13" Content="enabled">
<META HTTP-Equiv="scanner-i2of5ConvertToEAN13" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">