Overview
The Code39fullAscii Decoder Setting is used to set the Code39fullascii property which enables or disables full ASCII conversion of the bar code.
Syntax
code39fullAscii (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="Code39fullascii:[parameter]"> |
code39fullAscii JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the code39fullAscii. |
To Set code39fullAscii parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.code39FullAscii = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
code39FullAscii:[Value] | true/false | Enables/Disables full ASCII conversion of the bar code. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports Code39. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only Code39 labels with the fullascii property set to true:
<META HTTP-Equiv="scanner" Content="Code39:enabled">
<META HTTP-Equiv="scanner" Content="Code39fullascii:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="Code39:enabled;Code39fullascii:true;enabled">
or
<META HTTP-Equiv="scanner-Code39" Content="enabled">
<META HTTP-Equiv="scanner-Code39fullascii" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">