Overview
The Code39convertToCode32 Decoder Setting is used to enable conversion from Code39 to Code32 bar code. If this flag is set, the bar code is converted to Code32, and Code32 parameters are used.
Syntax
code39convertToCode32 (Decoder Setting) <META> Syntax |
---|
<META HTTP-Equiv="scanner" content="Code39ConvertToCode32:[parameter]"> |
code39convertToCode32 JavaScript Object Syntax: |
---|
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the code39convertToCode32. |
To Set code39convertToCode32 parameters via JavaScript use the following syntax: scanner.Parameter = Value;
e.g. scanner.code39convertToCode32 = Value; |
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
Name | Possible Values | Description | Default Value |
---|---|---|---|
code39convertToCode32:[Value] | true/false | Enables/Disables the property. | Device specific |
Requirements
RhoElements Version | 1.0.0 or above |
---|---|
Supported Devices | All supported devices. |
Minimum Requirements | Scanner or Imager module and device that supports Code39. |
Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled |
HTML/JavaScript Examples
The following example enables the scanner to read only Code39 labels with the ConvertToCode32 property set:
<META HTTP-Equiv="scanner" Content="Code39:enabled">
<META HTTP-Equiv="scanner" Content="Code39ConvertToCode32:true">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="Code39:enabled;Code32:enabled;Code39ConvertToCode32:true;enabled">
The following example enables the scanner to read only Code39 labels with the ConvertToCode32 property set:
<META HTTP-Equiv="scanner-Code39" Content="enabled">
<META HTTP-Equiv="scanner-Code39ConvertToCode32" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">