Code128ean128 Decoder Setting

RhoElements 2.x API

Overview

The Code128ean128 Decoder Setting is used to set the code128-ean128 property to enable the EAN128 subtype.

Syntax

code128ean128 (Decoder Setting) <META> Syntax

<META HTTP-Equiv="scanner" content="code128ean128:[parameter]">

code128ean128 JavaScript Object Syntax:
By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the code128ean128.
To Set code128ean128 parameters via JavaScript use the following syntax: scanner.Parameter = Value;

e.g. scanner.code128Ean128 = Value;

Parameters

Items listed in this section indicate parameters, or attributes which can be set.

NamePossible ValuesDescriptionDefault Value
code128Ean128:[Value] true/falseEnables the EAN128 subtype.Device specific

Requirements

RhoElements Version1.0.0 or above
Supported DevicesAll supported devices.
Minimum RequirementsScanner or Imager module and device that supports Code128.
PersistenceTransient - Decoder settings are only guaranteed to persist until the Scanner is disabled

HTML/JavaScript Examples

The following example enables the scanner to read only codabar labels with the EAN128 subtype property set

<META HTTP-Equiv="scanner" Content="codabar:enabled">
<META HTTP-Equiv="scanner" Content="code128ean128:true">
<META HTTP-Equiv="scanner" Content="enabled">

Above example can also be written as shown below:

<META HTTP-Equiv="scanner" Content="codabar:enabled;code128ean128:true;enabled">

or

<META HTTP-Equiv="scanner-codabar" Content="enabled">
<META HTTP-Equiv="scanner-code128ean128" Content="true">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">