Overview
The Msi Decoder is used to enable or disable the msi decoder.
Syntax
| msi (Decoder) <META> Syntax | 
|---|
<META HTTP-Equiv="scanner" content="msi:[parameter]">  | 
| msi JavaScript Object Syntax: | 
|---|
| By default the JavaScript Object 'scanner' will exist on the current page and can be used to interact directly with the msi. | 
| 
To Set msi parameters via JavaScript use the following syntax: scanner.Parameter = Value;
 e.g. scanner.msi = Value;  | 
Parameters
Items listed in this section indicate parameters, or attributes which can be set.
| Name | Possible Values | Description | Default Value | 
|---|---|---|---|
| msi:[Value] | enabled/Disabled | Enables/Disables the msi decoder. | Device specific | 
Requirements
| RhoElements Version | 1.0.0 or above | 
|---|---|
| Supported Devices | All supported devices. | 
| Minimum Requirements | Scanner or Imager module and device that supports MSI. | 
| Persistence | Transient - Decoder settings are only guaranteed to persist until the Scanner is disabled | 
HTML/JavaScript Examples
The following example enables the scanner to read only msi labels:
<META HTTP-Equiv="scanner" Content="allDecoders:disabled">
<META HTTP-Equiv="scanner" Content="msi:enabled">
<META HTTP-Equiv="scanner" Content="enabled">
Above example can also be written as shown below:
<META HTTP-Equiv="scanner" Content="allDecoders:disabled;msi:enabled;enabled">
or
<META HTTP-Equiv="scanner-all_decoders" Content="disabled">
<META HTTP-Equiv="scanner-msi" Content="enabled">
<META HTTP-Equiv="scanner-enabled" Content="SCN1">
The following example enables the scanner to read all labels except msi:
<META HTTP-Equiv="scanner" Content="allDecoders:enabled">
<META HTTP-Equiv="scanner" Content="msi:disabled">
<META HTTP-Equiv="scanner" Content="enabled">