ScannerConfig.DecoderParameters+Code39Decoder

EMDK For Xamarin 2.6

The Code39 class provides access to parameters that are available for the Code39 decoder.

Type - Symbol.XamarinEMDK.Barcode.ScannerConfig+DecoderParameters+BaseDecoder

Properties

ConvertToCode32

Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.

Type - System.Boolean

FullAscii

Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII character set.

Type - System.Boolean

Length1

Use to set decode lengths. The valid range is 0 to 55.

Type - System.Int32

Length2

Use to set decode lengths. The valid range is 0 to 55.

Type - System.Int32

ReducedQuietZone

Flag to Enable or Disable decoding of Code 39 barcodes with reduced quiet zones. If you enable, select a OneDQuietZoneLevel to set the effort level.

Type - System.Boolean

Redundancy

Sets the reader to read the bar code twice before accepting data.

Type - System.Boolean

ReportCheckDigit

Transmit Code 39 data with or without the check digit.

Type - System.Boolean

ReportCode32Prefix

Scan the appropriate bar code to enable or disable adding the prefix character "A" to all Code 32 bar codes.

Type - System.Boolean

SecurityLevel

Options: Security level 0 , Security Level 1 , Security Level 2 and Security Level 3. Use enum ScannerConfig.SecurityLevel.

Type - Symbol.XamarinEMDK.Barcode.ScannerConfig+SecurityLevel

VerifyCheckDigit

Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check digit.

Type - System.Boolean