Overview
To get Barcode data into an application, create a profile with two profile features selected:
The Barcode
feature in the Profile Manager is responsible for reading data from the device's integrated barcode scanner and supports different types of barcode readers including laser, imager and internal camera. It also contains detailed parameters for scanner behavior as well as individual barcode symbology parameters.
The Intent
, Keystroke
or IP
feature in the Profile Manager is used to define how the output from the Barcode scanner should be handled
Intent - The Intent feature, in the Profile Manager, collects and sends data received from the Barcode scanner to your application using the Android Intent mechanism. To use this, you should be familiar with how to register to receive intents in your application as well as handling the data that is passed in. You will have the ability to configure how the intent is sent to your application in the profile itself.
Keystroke - The Keystroke feature, in the Profile Manager, collects and sends data received from the Barcode scanner to your application by emulating keystrokes. You will have the option to control how the data is sent as well as if it should have any prefix or suffix automatically added using basic data formatting.
IP - IP Output allows DataWedge to send captured data to a host computer via a network connection. Captured data can be sent over an IP network to a specified IP address and port using either TCP or UDP transport protocols.
Name
The name field is used by the EMDK to identify this particular feature parameter set when you want to manage just part of the profile programmatically using the EMDK ProfileManager API. This can be useful if you have multiple types of the same feature and want to update only one of them without having to update the whole profile. See EMDK Profiles Overview for more information.
Note: As of EMDK 6.8, DataWedge can no longer be configured for data capture through Profile Manager. Zebra recommends using the DataWedge APIs instead.
Enabled
Enables or disables this feature. Default is enabled.
Scanner Selection
Configures which scanning device to use for data capture.
- Auto - Automatically determines the best scanning device. If a Scan Module or Scan/MSR Module is installed on the MC40, then the 2D imager is selected. Otherwise the camera is selected.
- Internal Laser 1 - Scanning is performed using the internal 1D laser scanner.
- Internal Imager 1 - Scanning is performed using the internal 2D scanner or MSR module.
- Internal Camera 1 - Scanning is performed with the rear-facing camera.
- Pluggable Laser 1 - Scanning is performed using an external 1D laser scanner plugged into the device.
- Bluetooth Imager 1 - Scanning is performed using an RS507 over Bluetooth.
- RS5000 Pluggable Imager - Scanning is performed using an RS5000 pluggable scanner.
- RS6000 Bluetooth Imager - Scanning is performed using an RS6000 over Bluetooth.
- DS3678 Bluetooth Imager - Scanning is performed using a DS3678 over Bluetooth.
- DS3608 Pluggable Imager - Scanning is performed using a DS3608 pluggable scanner.
Bluetooth scanners are supported according to the following rules:
- To initially configure the RS507 in a Profile, the scanner must be paired and connected.
- After initial configuration, the Bluetooth scanner can be enabled and disabled in the Profile even if it is disconnected from the device. However, to configure reader parameters, decoders and other scanner settings, the Bluetooth scanner must be connected.
- The device will not automatically reconnect to a Bluetooth scanner if that scanner is connected while it is using a different auto-selected scanner. To re-enable a Bluetooth scanner, connect the scanner and select it in the Profile or re-choose the Auto select option.
- Auto-selection and Battery Swap - If Scanner selection is set to Auto and the RS507 was enabled prior to a battery swap, DataWedge will continue working with that RS507 scanner upon reconnection after the battery is swapped. If the RS507 does not reconnect with after the swap, DataCapture will revert to the current default scanner.
Use Auto when not supported
When importing a Profile, this option sets the Scanner Selection to Auto if the scanner type contained in the incoming Profile is not supported on the target device.
Keep Enabled on Suspend
This mode is supported on Bluetooth and pluggable scanners only, and might result in faster battery drain than would otherwise be expected while in suspend mode.
Note: The Zebra computing device will wake from suspend mode when the RS507 scan trigger is pressed.
Decoders
Configures which barcode decoders are enabled or disabled. For best performance disable all unnecessary decoders. By default the most commonly used decoders are enabled (shown below with an asterisk). The supported decoders are:
- Australian Postal
- Aztec
- Canadian Postal
- Chinese 2 of 5
- Codabar*
- Code 11
- Code 39*
- Code 93
- Code 128*
- Composite AB
- Composite C
- Datamatrix*
- Discrete 2 of 5
- Dutch Postal
- EAN-8*
- EAN-13*
- GS1 DataBar*
- GS1 DataBar Expanded*
- GS1 DataBar Limited
- HAN XIN
- Japanese Postal
- Korean 3 of 5
- Interleaved 2 of 5
- Matrix 2 of 5
- Maxicode*
- MAIL MARK
- MicroPDF
- MicroQR
- MSI
- PDF417*
- QR Code*
- Signature
- TLC 39
- Trioptic 39
- UK Postal
- UPC-A*
- UPC-E0*
- UPC-E1
- US4State
- US4state FICS
- USPostnet
- USPlanet
- Webcode
UPCA
- Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the data. Enables or disables this option.
- Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System Character. There are three options for transmitting a UPCA preamble:
- Preamble None - Transmit no preamble.
- Preamble Sys Char - Transmit System Character only (default).
- Preamble Country and Sys Char - Transmit System Character and Country Code ("0" for USA). Select the appropriate option to match the host system.
UPCE0
- Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the data. Enables or disables this option.
- Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System Character. There are three options for transmitting a UPCE0 preamble:
- Preamble Sys Char - Transmit System Character only.
- Preamble Country and Sys Char - Transmit System Character and Country Code ("0" for USA).
- Preamble None - Transmit no preamble (default). Select the appropriate option to match the host system.
- Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion (default - disabled).
EAN-8
- Convert EAN8 To EAN13 - Enables or disables the conversion of EAN8 to EAN13.
Code128
- Length1 - Use to set decode lengths (default - 0).
- Length2 - Use to set decode lengths (default - 55).
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- Enable Plain Code 128 - Flag to enable other 128 sub types (besides GS1-128 and ISBT-128).
- Enable GS1-128 - Set the GS1 128 subtype.
- Enable ISBT128 - Set the ISBT128 subtype.
- ISBT128 Concatenation Mode - Select an option for concatenating pairs of ISBT code types:
- Concat Mode Never - Do not concatenate pairs of ISBT codes encountered (default).
- Concat Mode Always - There must be two ISBT codes in order to decode and perform concatenation. Does not decode single ISBT symbols.
- Concat Mode Auto - Decodes and concatenates pairs of ISBT codes immediately. If only a single ISBT symbol is present, the device must decode the symbol the number of times set via Redundancy - Code128 before transmitting its data to confirm that there is no additional ISBT symbol.
- Check ISBT Table - The ISBT specification includes a table that lists several types of ISBT barcodes that are commonly used in pairs. If ISBT128 Concat Mode is set, enable Check ISBT Table to concatenate only those pairs found in this table. Other types of ISBT codes are not concatenated.
- Security Level - The scanner offers four levels of decode security for Code 128 barcodes. Select increasing levels of security for decreasing levels of barcode quality. There is an inverse relationship between security and scanner aggressiveness, so choose only that level of security necessary for any given application.
- Security Level 0 - This setting allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding most "in-spec" barcodes.
- Security Level 1 - This setting eliminates most misdecodes.
- Security Level 2 - Select this option if Security level 1 fails to eliminate misdecodes.
- Security Level 3 - If Security Level 2 is selected and misdecodes still occur, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec barcodes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this level of security is needed, try to improve the quality of the barcodes.
- Code128 Reduced Quiet Zone - Code128 Reduced Quiet Zone
- Ignore Code128 FNC4 - Ignore Code128 FNC4
Code39
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths 4.
- Verify Check Digit - Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check digit (default - disabled).
- Report Check Digit - Transmit Code 39 data with or without the check digit.
- Full ASCII - Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII character set. To enable or disable Code 39 Full ASCII,
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- Convert Code39 To Code32 - Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate barcode below to enable or disable converting Code 39 to Code 32.
- Report Code32 Prefix - Scan the appropriate barcode to enable or disable adding the prefix character "A" to all Code 32 barcodes.
- Security Level - Options: Security level 0, Security Level 1, Security Level 2 and Security Level 3.
- Code39 Reduced Quite Zone - Code39 Reduced Quiet Zone
Interleaved 2of5
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- Check Digit
- No Check Digit - A check digit is not used.
- USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data complies with either the Uniform Symbology Specification (USS) check digit algorithm.
- OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data complies with either the Optical Product Code Council (OPCC) check digit algorithm.
- Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit.
- Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 barcodes to EAN-13, and transmit as EAN-13. The Interleaved 2 of 5 barcode must be enabled and must have a leading zero and a valid EAN-13 check digit.
- Security Level - The scanner offers four levels of decode security. Select increasing levels of security for decreasing levels of barcode quality.
- I2of5 Reduced Quiet Zone - I2of5 Reduced Quiet Zone
GS1 Data Bar Limited
- Security Level - The scanner offers four levels of decode security. Select increasing levels of security for decreasing levels of barcode quality.
Composite AB
- UCC Link Mode
- Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is detected.
- Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D component is not transmitted.
- Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D component, as well as the 2D portion if present. (default).
US Postnet
- Report Check Digit - Transmits US Postnet data with or without the check digit
US Planet
- Report Check Digit - Transmits US Planet data with or without the check digit
UK Postal
- Report Check Digit - Transmit UK Postal data with or without the check digit
Codabar
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- CLSI Editing - Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.
- NOTIS Editing - Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this feature if the host system requires this data format.
MSI
Length 1 - Use to set decode lengths.
Length 2 - Use to set decode lengths.
Redundancy - Sets the reader to read the barcode twice before accepting data.
Check Digit - With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is optional.
- One Check Digit - Verify one check digit.
- Two Check Digits - Verify two check digits.
Check Digit Scheme - Two algorithms are possible for the verification of the second MSI check digit.
Select the algorithm used to encode the check digit. * Mod-11-10 - First check digit is MOD 11 and second check digit is MOD 10. * Mod-10-10 - Both check digits are MOD 10.
- Report Check Digit - Transmit MSI data with or without the check digit.
Code93
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
Trioptic 39
- Redundancy - Sets the reader to read the barcode twice before accepting data.
Discrete 2 of 5
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
Code11
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- Verify Check Digit - Check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 barcode.
- No Check Digit - Do not verify check digit.
- 1 Check Digit - barcode contains one check digit.
- 2 Check Digits - barcode contains two check digits.
- Report Check Digit - Transmit Code 11 data with or without the check digit.
HAN XIN
- HAN XIN Inverse - HAN XIN Inverse
Matrix 2 of 5
- Length1 - Use to set decode lengths.
- Length2 - Use to set decode lengths.
- Redundancy - Sets the reader to read the barcode twice before accepting data.
- Report Check Digit - Transmit Matrix 2 of 5 data with or without the check digit.
- Verify Check Digit - Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that the data complies with a specified check digit algorithm.
UPCE1
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the data. Enables or disables this option.
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System Character. There are three options for transmitting a UPCE1 preamble:
- Preamble Sys Char - Transmit System Character only.
- Preamble Country and Sys Char - Transmit System Character and Country Code ("0" for USA).
- Preamble None - Transmit no preamble (default). Select the appropriate option to match the host system.
Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion.
Decode Lengths
The allowable decode lengths are specified by options Length1 and Length2 as follows:
- Variable length - Decode symbols containing any number of characters.
- Set both Length1 and Length2 to 0.
- Range - Decode a symbol with a specific length range (from a to b, including a and b).
- Set Length1 to a and set Length2 to b.
- Two Discrete Lengths - Decode only symbols containing either of two selected lengths.
- Set either Length1 or Length2 to the specific lengths.
- One Discrete Length - Decode only symbols containing a specific length.
- Set both Length1 and Length2 to the specific length.
UPC EAN Params
Allows the configuration of the parameters that apply to more than one UPC or EAN decoder.
Security Level - The scanner offers four levels of decode security for UPC/EAN barcodes. Select higher security levels for lower quality barcodes. There is an inverse relationship between security and decode speed, so be sure to choose only that level of security necessary for the application.
- Level 0 - This default setting allows the scanner to operate fastest, while providing sufficient security in decoding "in-spec" UPC/EAN barcodes.
- Level 1 - As barcode quality levels diminish, certain characters become prone to misdecodes before others (for example 1, 2, 7 and 8). If the scanner is misdecoding poorly printed barcodes, and the misdecodes are limited to these characters, select this security level.
- Level 2 - If the scanner is misdecoding poorly printed barcodes, and the misdecodes are not limited to characters 1, 2, 7, and 8, select this security level.
- Level 3 - If the scanner is misdecoding after having tried Level 2, select this security level. Be advised, selecting this option is an extreme measure against misdecoding severely out-of-spec barcodes. Selecting this level of security can significantly impair the decoding ability of the scanner. If this level of security is necessary, try improving barcode quality.
Supplemental2 - Enables or disables the length 2 supplementals.
Supplemental5 - Enables or disables the length 2 supplementals.
Supplemental Mode -
- No Supplementals - the scanner is presented with a UPC/EAN plus supplemental symbol, the scanner decodes UPC/EAN and ignores the supplemental characters.
- Supplemental Always - the scanner only decodes UPC/EAN symbols with supplemental characters, and ignores symbols without supplementals.
- Supplements Auto - the scanner decodes UPC/EAN symbols with supplemental characters immediately. If the symbol does not have a supplemental, the scanner must decode the barcode the number of times set via UPC/EAN Supplemental Redundancy before transmitting its data to confirm that there is no supplemental.
- Supplemental Smart - Enables smart supplementals. In this mode the decoder returns the decoded value of the main block right away if it does not belong to one of the following supplemental types: 378, 379, 977, 978, 979, 414, 419, 434 or 439. If the barcode starts with one of the prefixes it searches the image more aggressively for a supplemental. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
- Supplemental 378-379 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 378 or 379. Disables reading of supplementals for any other UPC/EAN barcode not starting with 378 or 379. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
- Supplemental 978-979 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 978 or 979. Disables reading of supplementals for another UPC/EAN barcode not starting with 978 or 979. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
- Supplemental 414-419-434-439 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 414, 419, 434 or 439. Disables reading of supplementals for another UPC/EAN barcode not starting with 414, 419, 434 or 439. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
- Supplemental 977 - Enables (auto-discriminate) supplemental for UPC/EAN codes starting with 977. Disables reading of supplementals for another UPC/EAN barcode not starting with 977. Tries to scan the supplemental if it is present. If the supplemental scanning failed, then the main barcode is returned.
Retry Count - Retry count for auto-discriminating for supplementals. Possible values are from 2-20. Note that this flag is only considered if Supplemental Mode - UPC EAN is set to one of the following values: Supplementals Auto, Supplementals Smart, Supplementals 378-379, Supplementals 978-979, Supplementals 977 or Supplementals 414-419-434-439 (2 to 20).
Random Weight Check Digit - Enable random weight check digit verification.
Bookland - Enable or disable this option.
Coupon - Enables Coupon code decoding. Note that in order to successfully decode Coupon codes, all of the correct decoders must be enabled.
Coupon Report Mode - Enables one of the coupon report modes
- Old Coupon Report Mode
- New Coupon Report Mode
- Both Coupon Report Mode
EAN Zero Extend - Enable this parameter to add five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols. Disable this to transmit EAN-8 symbols as is.
Bookland Format - if Bookland option is enabled, select one of the formats for Bookland data
- Format ISBN-10
- Format ISBN-13
Convert DataBar To UPC EAN - If this is set it converts DataBar barcodes to UPC/EAN format. For this setting to work UPC/EAN symbologies must be enabled.
UPC Reduced Quiet Zone - Enable decoding of marginless UPC barcodes
Reader Params
Allows the configuration of parameters specific to the selected barcode reader.
Aim Mode - Switch on/off scanner aiming while scanning.
Beam Timer - Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments of 100 ms). A value of 0 sets the reader to stay on indefinitely.
Adaptive Scanning - Enable/Disable Adaptive Scanning
Beam Width - Set Beam Width
- Narrow
- Normal
- Wide
Power Mode - Set scanner power mode
- Low Power Mode
- Optimized Power Mode
- High Power Mode
- Always On
Mobile Phone Display Mode - Defines finer reader by the DS457
- Disable Mobile Display Mode
- Enable Mobile Display Mode
Reader Mode - Defines how the SSI scanner triggers
- Presentation Mode
- Triggered Mode
Linear Security Level - Sets the number of times a barcode is read to confirm an accurate decode.
- Security Redundancy and Length - Two times read redundancy based on redundancy flags and code length.
- Security Short or Codabar - Two times read redundancy if short barcode or Codabar.
- Security All Twice - Two times read redundancy for all barcodes.
- Security Long and Short - Two times read redundancy for long barcodes, three times for short barcodes.
- Security All Thrice - Three times read redundancy for all barcodes.
Picklist - Allows the imager to decode only the barcode that is directly under the cross-hair/reticle (+) part of the pattern. This feature is useful in applications where multiple barcodes may appear in the field of view during a decode session and only one of them is targeted for decode.
- Disable - Disables Picklist mode. Any barcode within the field of view can be decoded.
- Enable (Centered) - Enables the Picklist mode so that only the barcode in the center of the image is decoded. This is most useful when used in conjunction with the static and dynamic reticle viewfinder modes. Note: This mode is only valid for decoder modules that supports a viewfinder. Attempting to set this for an unsupported decoder will result in an error (camera scanner only).
- Enable (Reticle) - Enables the Picklist mode so that only the barcode that is directly under the cross-hair (reticle) is decoded. This is useful when used in conjunction with the static and dynamic reticle viewfinder modes (scan module only)
Aim Type - Type Trigger Modes
- Trigger - For each trigger press, a single barcode can be scanned.
- Timed Hold – Once trigger is pressed, an aiming session is started for a time specified by Aim Timer. When this time expires, a decode session is started and scan beam will be visible. The decode session will remain active until the Beam Timer expires, the trigger is released or a barcode is decoded.
- Timed Release - Once the trigger is pressed, an aiming session is started and will continue until the trigger is released. If the Aim Timer is expired when the trigger is released, a decode session will be started with scan beam visible for a remaining time equal to the Beam Timer or until a barcode is decoded.
- Press and Release - The scan beam starts when the trigger is pressed and released. The decode session will remain active until the Beam Timer expires or a barcode is decoded.
- Continuous Read - A press and hold of the scan trigger will continuously scan barcodes. Not supported with the Zebra RS507 Bluetooth Ring Scanner.
- Press and Sustain - Continue the decode session until the Beam Timer is expired, barcode is decoded or read is canceled. This avoids unexpected cancellations of a read by subsequently pressing the trigger button of the device. If the trigger button of the device is pressed while the beam is ON, it has no effect.
Aim Timer - Sets the duration (in ms) for timed aim modes. Supports values from 0-60000, in steps of 100 (i.e. 0, 100, 200, 300...).
Same Zebra Timeout - Suppress decoding the same symbol within the specified time interval (in ms) while in Continuous Trigger Mode. Supports values from 0-5000, in steps of 500 (i.e. 0, 500, 1000, 1500...).
Different Zebra Timeout - Suppress decoding an additional symbol within the specified time interval (in ms) while in Continuous Trigger Mode. Supports values from 0-5000 in steps of 500 (i.e. 0, 500, 1000, 1500...).
Illumination mode - Enable/Disable illumination depending on ambient light conditions.
Keep pairing info after reboot - Enable/Disable automatic reconnection after scanner reboot. Applies to DS3678 Bluetooth scanner only.
LCD Mode - Enables/disables LCD mode. LCD mode enhances the ability of the imager to read barcodes from LCD displays such as cellphones (scan module only).
- Disable - Disables the LCD mode
- Enable - Enables LCD mode
Note: When using the LCD mode, a degradation in performance might be observed and the aiming crosshair might blink until the barcode is decoded.
HW Engine Low Power Timeout - Timeout value (in ms) for the scanner engine to enter Low Power mode. Supports values from 0-1000 in steps of 50 (i.e. 0, 50, 100, 150...).
Time Delay to Low Power - Time delay for scanner to enter low power mode
- 1 Second
- 30 Seconds
- 1 Minute
- 5 Minutes
Illumination Brightness Value - Illumination Brightness of the Imager
Inverse 1D Mode - This parameter allows the user to select decoding on inverse 1D barcodes.
- Disable - Disables decoding of inverse 1D barcodes.
- Enable - Enables decoding of only inverse 1D barcodes.
- Auto - Allows decoding of both positive and inverse 1D barcodes.
Viewfinder size - Viewfinder window size in camera scanner as a percentage of device display size from 0-100.
Viewfinder X offset - Viewfinder window position in X axis as a percentage of device screen width from 0-100.
- Viewfinder Y offset - Viewfinder window position in Y axis as a percentage of device screen height from 0-100.
1D Quiet Zone Level - Sets the effort at which the decoder will attempt to decode "marginless" barcodes:
- Level 0 - Decoder performs margin decoding as usual
- Level 1 - Decoder performs more aggressively
- Level 2 - Decoder requires only one side end of barcode
- Level 3 - Decoder decodes anything
Poor Quality Decode Effort - Permits selection of enhancement modes for decoding barcodes of poor or degraded quality. Available options:
- Level 0 - Decoding performance on regular 1D and 2D barcodes is not affected
- Level 1 - Scanner performance on regular 2-D barcodes is impacted; decoding performance on Tesco Thailand barcode and Suppository barcode is improved
- Level 2 - same as Level 1
- Level 3 - same as Level 1
Note: Performance is the same from Level 1 to Level 3.
Character Set Selection - Allows the user to convert the barcode data if different from default encoding type.
- UTF-8
- ISO-8859-1
- Shift_JIS
Viewfinder Mode - Configures the Viewfinder modes supported for camera scanning.
- Viewfinder Enabled - Enables only the viewfinder.
- Static Reticle - Enables the viewfinder and a red reticle in the center of the screen to aid in barcode selection.
Scanning Mode - Sets the desired scanning mode from the following options:
- Single – Scans only one barcode at a time.
- UDI – Attempts to decode UDI labels with multiple barcodes and optionally parses data according to the UDI standard.
- Multi-barcode – Scan multiple barcodes simultaneously.
Note: The Unique Device Identification (UDI) system was established in 2007 by the U.S. Food and Drug Administration as a means to track medical devices.
IMPORTANT:
Support for Unique Device Identification (UDI) standard barcodes such as GS1, HIBCC and ICCBBA in Barcode APIs has been deprecated. UDI support will end when EMDK targets devices running Android 10 Q.
Multi-barcode Notes
Picklist Behavior - In multi-barcode scanning mode, when a picklist reader parameter is set to a value other than “Disabled," the user is expected to move the crosshair to the specified number of barcodes to be scanned. Set this value (from 2-10) using the BarcodeCount
parameter. Data is returned only after the specified number of barcodes is read.
Decoding with duplicate barcodes - If a label to be scanned contains multiple barcodes, some of which are duplicates (with the same data and label type), only one barcode from the duplicates will be decoded; the remainder are ignored. If the label has two duplicate barcodes plus another two different barcodes, a maximum of three barcodes will be decoded and one will be ignored as a duplicate.
Decoding behavior with number of barcodes - Barcodes can be of multiple label types. If the required number of barcodes (from 1-10, as set using the BarcodeCount
parameter) is not in view of the scanner, the scanner will not decode any data. If the scanner's field of view contains a number of barcodes greater than the value set by BarcodeCount
, the scanner will randomly decode any barcode(s) until the count is reached. For example, if the count is set to two and eight barcodes are in the field of view, the scanner will return data for the first two barcodes it sees, and return the data in random order.
Scan Params
Allows the configuration of Code Id and decode feedback options.
- Code ID Type - A Code ID character identifies the code type of a scanned barcode. This is useful when the reader is decoding more than one code type. Select a code ID character to insert between the prefix and the decoded symbol.
- Code ID Type None - No prefix (default).
- Code ID Type Aim - A standards based three character prefix.
- Code ID Type Symbol - A symbol defined single character prefix.
Note: Not all ringtones are fully supported as decode tones. Ringtones of longer length may be truncated when used as a decode tone. Zebra recommends testing the selected tone(s) for desired operation before deployment.
Beep Volume Channel -
- Ringer
- Music and Media
- Alarms
- Notification
Decode Audio Feedback - Select an audio tone to sound upon a good decode.
- The audio tones stored as Application’s private data (i.e. cache, asset) should not be specified for this field to avoid access violation. Therefore any audio tones meant for this purpose must be stored under shared public directories (i.e. /Music, /Ringtones, etc.) or in shared external storage.
Decode Haptic Feedback - Enable the MC40 to vibrate upon a good decode.
BT Disconnect On Exit - Enable/Disable Bluetooth disconnect on exit.
Connection Idle Time - If a Bluetooth-scanner associated application is opened, the Bluetooth scanner will be automatically disconnected after this Connection Time duration of inactivity. From 60 to 1800, Steps of 5. Eg: 60, 65, 70, 75...
Establish Connection Time - Time (from 30-60 seconds) that the
enable
method will be blocked before returning if a Bluetooth scanner connection is not established.Display BT Address Barcode - If this value is set to true, the Bluetooth Pairing Utility Application will be opened when the enable method is called.
Decode Feedback LED Timer - Defines the length of time (in ms) to flash the Green LED to indicate a successful decode.
Decoding LED Notification - When enabled, causes the Red LED to flash when the scan trigger is pressed.
- Engine Decode LED - Controls Engines' decode LED behavior
- Disabled
- Off on power down
- Power down only after LED off
UDI Params
Enable UDI-GS1 - Enable/Disable GS1 format decoding.
Enable UDI-HIBCC - Enable/Disable HIBCC format decoding.
Enable UDI-ICCBBA - Enable/Disable ICCBBA format decoding.
Multi-barcode Params
- Barcode count - Number of barcodes (from 2-10) to decode.
Output Data
For an application to receive barcode data, one or more Output Features must be specified. See individual reference documentation for more information: