ProfileConfig.DataCapture.Barcode.DecoderParams.UPCE0

EMDK For Android 5.0

Holds UPCE0 configuration settings.

Example Usage:


UPCE0 upce0 = profileConfig.dataCapture.barcode.decoderParams.upce0;

Public Fields

report_check_digit

The check digit is the last character of the symbol used to verify the integrity of the data. Enables or disables this option (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


upce0.report_check_digit = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

preamble

Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Select the appropriate option to match the host system. Use enum ProfileConfig.PREAMBLE.

Example Usage:


upce0.preamble = PREAMBLE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.PREAMBLE

convert_to_upca

Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, the data follows UPC-A format and is af fected by UPC-A programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


upce0.convert_to_upca = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE