ScannerConfig.ReaderParams.ReaderSpecific.LaserSpecific

EMDK For Android 5.0

LaserSpecific class provides access to the laser scanner specific parameters.

Public Fields

continuousRead

ContinuousRead class provides access to continuous scanning related parameters.

Type:

com.symbol.emdk.barcode.ScannerConfig.ReaderParams.ReaderSpecific.ContinuousRead

beamTimer

Sets the maximum amount of time that the reader remains on (0 - 60,000 ms in increments of 100 ms). A value of 0 sets the reader to stay on indefinitely.

Example Usage:


readerParams.beamTimer = 1500;

Type:

int

linearSecurityLevel

Sets the number of times a bar code is read to confirm an accurate decode. Use enum ScannerConfig.LinearSecurityLevel.

Example Usage:


readerParams.linearSecurityLevel = LinearSecurityLevel.ALL_THRICE;

Type:

com.symbol.emdk.barcode.ScannerConfig.LinearSecurityLevel

inverse1DMode

This parameter allows the user to select decoding on inverse 1D bar codes. Use enum ScannerConfig.Inverse1DMode.

Example Usage:


readerParams.cameraSpecific.inverse_1d_mode = Inverse1DMode.AUTO;

Type:

com.symbol.emdk.barcode.ScannerConfig.Inverse1DMode

powerMode

Set scanner power mode. Use enum ScannerConfig.PowerMode.

Type:

com.symbol.emdk.barcode.ScannerConfig.PowerMode