ProfileConfig.DataCapture.Barcode.DecoderParams.Code39

EMDK For Android 4.2

Holds Code39 configuration settings.

Example Usage:


Code39 code39 = profileConfig.dataCapture.barcode.decoderParams.code39;

Public Fields

length1

Use to set decode lengths (default - 0).

Example Usage:


int length1 = code39.length1;

Type:

int

length2

Use to set decode lengths 4 (default - 55).

Example Usage:


int length2 = code39.length2;

Type:

int

verify_check_digit

Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check digit (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.verify_check_digit = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

report_check_digit

Transmit Code 39 data with or without the check digit (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.report_check_digit = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

full_ascii

Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII character set (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.full_ascii = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

redundancy

Sets the reader to read the bar code twice before accepting data (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.redundancy = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

convert_to_code32

Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.convert_to_code32 = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

report_code32_prefix

Scan the appropriate bar code to enable or disable adding the prefix character "A" to all Code 32 bar codes (default - disabled). Use enum ProfileConfig.ENABLED_STATE.

Example Usage:


code39.report_code32_prefix = ENABLED_STATE.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.ENABLED_STATE

security_level

Options: Security level 0 , Security Level 1 , Security Level 2 and Security Level 3 (default - Security level 1). Use enum ProfileConfig.SECURITY_LEVEL.

Example Usage:


code39.security_level = SECURITY_LEVEL.DEFAULT;

Type:

com.symbol.emdk.ProfileConfig.SECURITY_LEVEL