ScannerConfig.DecoderParams.CodaBar

EMDK For Android 4.0

The CodaBar class provides access to parameters that are available for the CodaBar decoder.

Public Fields

length1

Use to set decode lengths. The supported range is 0 to 55.

Example Usage:



codabar.length1 = 6;

Type:

int

length2

Use to set decode lengths. The supported range is 0 to 55.

Example Usage:



codabar.length2 = 55;

Type:

int

redundancy

Sets the reader to read the bar code twice before accepting data.

Example Usage:



codabar.redundancy = true;

Type:

boolean

clsiEditing

Enable this parameter to strip the start and stop characters and insert a space after the first, fifth, and tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data format.

Example Usage:



codabar.clsi_editing = true;

Type:

boolean

notisEditing

Enable this parameter to strip the start and stop characters from a decoded Codabar symbol. Enable this feature if the host system requires this data format.

Example Usage:



codabar.notis_editing = true;

Type:

boolean