ScannerConfig.DecoderParams.Code39

EMDK For Android 2.3

The Code39 class provides access to parameters that are available for the Code39 decoder.

Public Fields

length1

Use to set decode lengths. The valid range is 0 to 55.

Example Usage:


code39.length1 = 0;

Type:

int

length2

Use to set decode lengths. The valid range is 0 to 55.

Example Usage:


code39.length2 = 55;

Type:

int

verifyCheckDigit

Enable this feature to check the integrity of all Code 39 symbols to verify that the data complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check digit.

Example Usage:


code39.verifyCheckDigit = false;

Type:

boolean

reportCheckDigit

Transmit Code 39 data with or without the check digit.

Example Usage:


code39.reportCheckDigit = true;

Type:

boolean

fullAscii

Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII character set.

Example Usage:


code39.fullAscii = true;

Type:

boolean

redundancy

Sets the reader to read the bar code twice before accepting data.

Example Usage:


code39.redundancy = true;

Type:

boolean

convertToCode32

Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.

Example Usage:


code39.convertToCode32 = true;

Type:

boolean

reportCode32Prefix

Scan the appropriate bar code to enable or disable adding the prefix character "A" to all Code 32 bar codes.

Example Usage:


code39.reportCode32Prefix = true;

Type:

boolean

securityLevel

Options: Security level 0 , Security Level 1 , Security Level 2 and Security Level 3. Use enum ScannerConfig.SecurityLevel.

Example Usage:


code39.securityLevel = SecurityLevel.LEVEL_1;

Type:

com.symbol.emdk.barcode.ScannerConfig.SecurityLevel