ScannerConfig.DecoderParams.Code11

EMDK For Android 4.2

The Code11 class provides access to parameters that are available for the Code11 decoder.

Public Fields

length1

Use to set decode length. The supported range is 0 to 55.

Example Usage:


code11.length1 = 4;

Type:

int

length2

Use to set decode length. The supported range is 0 to 55

Example Usage:


code11.length2 = 55;

Type:

int

redundancy

Sets the reader to read the bar code twice before accepting data.

Example Usage:


code11.redundancy = true;

Type:

boolean

verifyCheckDigit

Check the integrity of all Code 11 symbols to verify that the data complies with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar code. Use enum ScannerConfig.VerifyCheckDigit.

Example Usage:


code11.verifyCheckDigit = VerifyCheckDigit.NO;

Type:

com.symbol.emdk.barcode.ScannerConfig.VerifyCheckDigit

reportCheckDigit

Transmit Code 11 data with or without the check digit.

Example Usage:


code11.reportCheckDigit = false;

Type:

boolean